Special-use accommodation on bush fire prone land in NSW

A group home on bush fire prone land is assessed as a building for people who need help to leave. That changes the approval and the site plan.

What approvals does special-use accommodation need on bush fire prone land in NSW?

In NSW, group homes and seniors housing are special fire protection purposes. On bush fire prone land they need a bush fire safety authority from the NSW Rural Fire Service under the Rural Fires Act 1997. The design has to satisfy Planning for Bush Fire Protection 2019, covering asset protection zones, access, water and evacuation planning.

A group home or a seniors housing project on bush fire prone land in NSW needs a bush fire safety authority from the NSW Rural Fire Service before it can go ahead. Both uses are special fire protection purposes under section 100B of the Rural Fires Act 1997, because the people living in them can need help to leave when a fire comes.

Hospitals, schools and child care centres sit in the same group. For special-use accommodation, this is one of the first checks at feasibility.

Bush fire prone land

Each council maps the bush fire prone land in its area, and the Commissioner of the NSW Rural Fire Service certifies the maps. Large parts of the Blue Mountains, the Central Coast, the Hawkesbury and the Sutherland Shire are mapped, along with land on the edges of many regional towns.

The check is a map search. You can look up a property on the NSW Planning Portal spatial viewer or with the Rural Fire Service's online tool. The mapping includes a buffer around the vegetation itself, so a lot that looks well clear of the bush can still be on it.

The approval

A development application for a special fire protection purpose on bush fire prone land is integrated development under the Environmental Planning and Assessment Act 1979. The council refers it to the Rural Fire Service. The service sets its terms of approval and issues the bush fire safety authority.

The application carries a bush fire assessment report from a bush fire consultant, showing how the proposal satisfies Planning for Bush Fire Protection 2019. That is the Rural Fire Service guideline for development on bush fire prone land in NSW, and special fire protection purposes have a chapter of their own in it.

Why the bar is higher

A household in an ordinary house can leave early or shelter in a well-built home. Residents of a group home or a seniors housing building often rely on staff to move, and some use wheelchairs or need help to transfer. The guideline asks more of the site as a result.

Its main tool is the asset protection zone, the managed land between the building and the vegetation. For a special fire protection purpose that zone is wider than for a house, so less heat reaches the building and people have more time to get out.

Access, water and the plan

The guideline also covers roads a fire truck can use, a water supply for firefighting and where gas and electricity services run. Each one takes room on the site. Together they can decide how many dwellings the land can carry.

A special fire protection purpose also needs a bush fire emergency management and evacuation plan. On supported accommodation that plan is written around how the provider manages the home, including who is on overnight and how each resident moves, so the provider joins the conversation at the start.

How the building is built

Construction on bush fire prone land follows AS 3959, which sets requirements by bushfire attack level, from BAL-LOW up to BAL-FZ, the flame zone. Embers do most of the damage. So the work is in the detail, with sealed gaps, screened openings and rated glazing, as covered in how does a factory-built home handle bushfire and flood risk.

Level paths out

An evacuation plan only works if residents can actually leave the building. Level paths from each bedroom and living area to the outside, and on to the assembly area, matter as much as the fire rating of the walls. How exits are planned for people who need assistance is set out in emergency egress in supported accommodation.

Where it fits in the project

These requirements shape the site plan, so we resolve them at feasibility. Whether the project is a group home in planning terms, explained in what is a group home in NSW, decides whether these rules apply or the rules for an ordinary dwelling do.

MADEmodular / MADEbetter.

Our standards. Discuss your project.

MADEmodular / MADEbetter.

Let's talk.

Special-use accommodation, made better.